Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Arq. bras. cardiol ; 119(1): 48-56, abr. 2022. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1383717

ABSTRACT

Resumo Fundamento A oclusão do apêndice atrial esquerdo (AAE) tem se mostrado uma alternativa à terapia de anticoagulação oral (ACO) para prevenção de acidente vascular cerebral (AVC) em pacientes com fibrilação atrial não valvar (FANV). Objetivos Descrever os primeiros resultados de uma experiência inicial multicêntrica no Brasil e investigar a viabilidade, a segurança e a eficácia da oclusão do AAE com o novo dispositivo LAmbre. Métodos Coletamos dados do procedimento e do acompanhamento de 51 pacientes consecutivos com FANV, restrições para ACO em longo prazo e com anatomia adequada, submetidos à oclusão do AAE com o dispositivo LAmbre em 18 centros no Brasil. Indicações para o procedimento foram: sangramento importante em pacientes recebendo ACO (47,1%), AVC ou trombo persistente no AAE apesar de ACO adequada (27.5%), sangramento e AVC (17.6%), outras contraindicações clínicas apara ACO (5,9%), e escolha do paciente devido à prática esportiva (1,9%). Resultados Foram estudados 25 homens (49%) e 26 mulheres (51%), com idade média de 76±7,7 anos, escore CHA2DS2-VASc médio de 4,6± 1,7 e escore HAS-BLED médio de 3.4± 1,1. A taxa de sucesso do procedimento foi de 100%. As complicações imediatas relacionadas ao procedimento foram derrame pericárdico em dois pacientes, e embolização do dispositivo em um caso. Não foram observados shunts residuais > 5mm. Shunts < 5mm foram detectados em quatro pacientes por Doppler colorido ao final do procedimento. Após um período médio de acompanhamento de 18 meses ± 12 meses, não foram observados óbito, AVC ou complicações maiores. Conclusão A oclusão do AAE com o dispositivo LAmbre foi segura e eficaz nesta pequena série de casos. Apesar desses resultados iniciais encorajadores, dado o pequeno número de casos, serão necessários mais estudos com um maior período de acompanhamento.


Abstract Background Left atrial appendage (LAA) closure has been an alternative to oral anticoagulation (OAC) for stroke prevention in patients with non-valvular atrial fibrillation (NVAF). Objectives To report the first results of an initial multicenter experience in Brazil and to investigate the feasibility, safety, and efficacy of LAA closure with the new LAmbre device. Methods We collected procedural and follow-up data of 51 consecutive patients with non-valvular atrial fibrillation, restrictions for long-term OAC and suitable anatomy that underwent LAA closure with the LAmbre device in 18 centers in Brazil. Procedural indications were significant bleeding under OAC (47.1%), stroke or persistent LAA thrombus despite OAC (27.5%), bleeding plus stroke (17.6%), other clinical contraindications for OAC (5.9%), and patient's choice due to sports practice (1.9%). Results Twenty-five men (49%) and 26 women (51%), with a mean age of 76±7.7 years, mean CHA2DS2-VASc score of 4.6± 1.7 and mean HAS-BLED score of 3.4± 1.1 were studied. Procedural success rate was 100%. Procedure-related immediate complications were pericardial effusion in two patients, and immediate device embolization in one case. No large residual shunts (> 5 mm) were observed, and small shunts (<5mm) were detected in four patients by color Doppler at the end of the procedure. After a mean follow-up of 18 ± 12 months, there were no deaths, strokes nor any other major complications. Conclusion LAA occlusion with the LAmbre device was safe and effective in this small case series. Despite these encouraging initial results, the small number of cases warrants further studies with longer-term follow-up.

2.
J. Transcatheter Interv ; 30: eA20220004, 20220101. ilus
Article in English, Portuguese | LILACS-Express | LILACS | ID: biblio-1399114

ABSTRACT

Apresentamos o caso debutante na América Latina de reparos transcateteres edge- to-edge nas valvas mitral e tricúspide em um único procedimento em paciente de alto risco para cirurgia. A paciente evoluía com insuficiência cardíaca e limitações em suas atividades diárias quando foi submetida ao procedimento, no qual foram realizados os reparos transcateteres das valvas mitral e tricúspide. Aos 6 meses de evolução, estava assintomática e realizando suas atividades diárias. Debatemos as recomendações mais atualizadas sobre a terapia transcateter para coexistência dessas doenças valvares, assim como expomos as lacunas no conhecimento.


We present the first case in Latin America of transcatheter edge-to-edge mitral and tricuspid valve repair in a single procedure, in a patient at high risk for surgery. The patient progressed to heart failure and limitation in her daily living activities when she was submitted to transcatheter mitral and tricuspid valve repair. Six months later, she was asymptomatic and performing her daily living activities. We discuss the most updated recommendations for transcatheter repair when both valvar conditions coexist, and show the knowledge gaps.

4.
Rev. bras. cardiol. invasiva ; 23(3): 177-182, jul.-set.2015. ilus, tab
Article in Portuguese | LILACS | ID: lil-794194

ABSTRACT

A fibrilação atrial (FA) aumenta o risco de eventos tromboembólicos por êmbolos origina do sem apêndice atrial esquerdo (AAE). Métodos mecânicos para a oclusão do AAE foram desenvolvidos como alternativa à anticoagulação oral. O objetivo deste trabalho foi apresentar uma experiência inicial com o AMPLATZER® Cardiac Plug. Métodos: Incluímos pacientes com FA permanente ou paroxística, que apresentavam contraindicações ou complicações derivadas da anticoagulação oral. Pacientes com anatomia e medidas do AAE compatíveis com o oclusor, e sem trombos foram selecionados por meio de ecocardiograma transesofágico. Resultados: Foram realizados 14 procedimentos em 13 pacientes (5M:8F), com média de idade de 66,7 anos. Sangramento significativo e acidentes vasculares cerebrais prévios foram encontrados em 69,2% e em 53,8%, respectivamente. A FA era permanente em 84,6% e paroxística no restante da amostra. Os diâmetros médiodo óstio e da zona alvo mediram 23,9 mm e 20,8 mm, respectivamente. AAE bilobulados foram observados em 76,9%. Os procedimentos foram possíveis em todos os casos. Dezesseis dispositivos foram usados em 13 pacientes, numa razão de 1,2:1, e apenas 1 paciente precisou de um segundo dispositivo para oclusão do AAE. O tempo médio de acompanhamento foi de 12,2 meses. Todos os AAE permanecem fechados e sem defeito residual até o momento. Houve apenas um óbito tardio não relacionado ao procedimento. Conclusões: A oclusão do AAE com o dispositivo de AMPLATZER® Cardiac Plug mostrou ser segura e eficaz nesta pequena série de pacientes. Os resultados iniciais são encorajadores e apontam para o fechamento transcateter do AAE como alternativa para a anticoagulação oral em pacientes selecionados...


Atrial fibrillation (AF) increases the risk of thromboembolic events caused by embolioriginating in the left atrial appendage (LAA). Mechanical methods for LAA occlusion have been developed as an alternative to oral anticoagulation. The aim of this study was to present an initial experience with the AMPLATZER® Cardiac Plug. Methods: Patients with permanent or paroxysmal AF and with contraindications or complications of oral anticoagulation were included. Patients with LAA anatomy and measures compatible with the occluder, and without thrombi, were selected through transesophageal echocardiography. Results: A total of 14 procedures were performed in 13 patients (5M:8F), with mean age of 66.7 years. Significant bleeding and previous strokes were found in 69.2% and 53.8%, respectively. AF was permanent in 84.6% and paroxysmal in the remainder. The mean diameters of the ostium and the landing zone were 23.9 mm and 20.8mm, respectively. Bilobulated LAA was observed in 76.9%. Procedures were possible in all cases. Sixteen devices were used in 13 patients, a ratio of 1.2:1, and only one patient required a second device for LAA occlusion. The mean follow-up was 12.2 months. All LAA remain closed, with no residual defect to date. There was only one late death, unrelated to the procedure. Conclusions: LAA occlusion using the AMPLATZER® Cardiac Plug device was shown to be safe and effective in this small series of patients. The initial results are encouraging and indicate the transcatheter closure of the LAA as an alternative to oral anticoagulation therapy in selected patients...


Subject(s)
Humans , Male , Female , Middle Aged , Aged, 80 and over , Stroke , Anticoagulants/administration & dosage , Anticoagulants/therapeutic use , Atrial Fibrillation/prevention & control , Thromboembolism/prevention & control , Prostheses and Implants , Angiography/methods , Catheters , Echocardiography, Transesophageal/methods , Risk Factors , Heparin/administration & dosage , Heart Atria
5.
Arq. bras. cardiol ; 70(1): 37-42, jan. 1998. tab
Article in Portuguese | LILACS | ID: lil-218502

ABSTRACT

OBJETIVO: Avaliar retrospectivamente, implante de stent (IS) em paciente com doença arterial coronária (DAC), realizado em 7 hospitais do Rio de Janeiro. Métodos: De junho/94 a dezembro/96, foram realizados 2.220 procedimentos, e desses, Analisados 783 IS em 660 (29,7 "por cento" pacientes, através da coronariografia sem subtraçäo digital. Os diversos tipos de stent, mais frequênte, usados foram: Palmaz-Schatz (40,9 "por cento"), Gianturco-Roubin (29,1 "por cento" ) e NIR (22,0 "por cento"). As indicaçöes para o IS foram: lesäo de novo, 67,9 "por cento"; lesäo reestenótica, 16,0 "por cento"; lesäo com resultado subótimo da angioplastia transluminal coronária (ATC), 8,2 "por cento"; oclusäo aguda ou provável pós-ATC, 4,9 "por cento"; oclusäo crônica, 3,0 "por cento". Todos os stents foram implantados com alta pressäo, sem controle pelo ultra-som intracoronário. A prevençäo da trombose subaguda, na maioria dos pacientes (87,8 "por cento", foi feita com o uso de ticlopidina e ácido acetil-salicílico. RESULTADOS: Evoluçä imediata: a) sucesso no IS em 770 lesöes: 98,0 "por cento" em 646 (97,9 "por cento") pacientes; b)sucesso clínico em 634 (96,0 "por cento") casos; c) complicaçöes maiores : infarto agudo do miocárdio (IAM) - 1,1 "por cento"; cirurgia de revascularizaçäo miocárdica (CRM) - 1,4 "por cento" e óbito - 0,8 "por cento"; d) complicaçöes vasculares com correçäo cirúrgico e/ou sangramento - 3,0 "por cento". Evoluçäo tardia: a) dos 399 (60,4 "por cento") pacientes acompanhados clinicamente, a coronariografia de 121 (30,3 "por cento") mostrou retorno da lesäo no IS em 79 (19,8 "por cento") casos; b) frequência de outros eventos: IAM - 1,5 "por cento"; CRM - 2,3 "por cento"; óbito - 1,0 "por cento" e outra ATC ou procedimento similar - 12,5 "por cento". CONCLUSÄO: O estudo multicêntrico mostrou que o IS na DAC pode ser realizado com segurança , alto índice de sucesso imediato, poucas complicaçöes e baixa taxa de eventos cardíacos na evolucäo tardia.


Subject(s)
Humans , Male , Female , Adult , Aged , Middle Aged , Coronary Disease/surgery , Stents , Aged, 80 and over , Brazil , Follow-Up Studies , Postoperative Complications , Retrospective Studies
6.
Arq. bras. cardiol ; 69(1): 47-50, jul. 1997. ilus
Article in Portuguese | LILACS | ID: lil-214036

ABSTRACT

Descrevem-se dois casos de angioplastia transluminal coronária (ATC) com implante de stents em bifurcaçäo de coronária descendente anterior (DA) com artéria diagonal (DI), destacando-se as técnicas utilizadas. No caso 1, implantou-se na DA um flexistent Gianturco-Roubin (GR) e através de suas hastes, um Palmaz-Schatz (PS) no óstio de DI, com suceso. O reestudo angiográfico em sete meses mostrou ausência de reestenose. No caso 2, implantou-se metade de um stent PS em DA e outro PS em DI, nesta ordem, também com sucesso. No seguimento clínico de seis meses, paciente encontra-se assintomático.


Subject(s)
Humans , Middle Aged , Male , Angina, Unstable , Angioplasty, Balloon, Coronary , Coronary Disease/therapy , Stents
7.
Arq. bras. cardiol ; 68(3): 193-197, Mar. 1997.
Article in Portuguese | LILACS | ID: lil-320347

ABSTRACT

We describe a case of coronary stenosis located in an unprotected left main coronary artery, treated primarily and electively with the placement of a coronary stent. As a function of the large mass of myocardium involved, this patient would be considered a classical candidate for direct surgery, because the inherent risk involved with conventional balloon angioplasty, mainly due to the eventual occurrence of acute closure during the procedure. Since the previsibility of the immediate results with the use of coronary stents was significantly improved, we propose this new therapeutic approach for this traditionally surgical case, that has been performed with success and without any complication. This strategy for the treatment of unprotected left main lesions with the elective placement of Palmaz-Schatz stents, has not yet been proposed or applied in our country, and may represent a new universe of indication of percutaneous treatment of coronary artery disease, no longer approaching the left main stem only in special or emergency situations, usually a result of complications of left main manipulation during angioplasty of the coronary system. The patient involved in this case did not show any contraindication for the treatment with conventional open heart surgery.


Subject(s)
Humans , Male , Middle Aged , Stents , Coronary Disease , Angioplasty, Balloon, Coronary/methods , Stents , Coronary Disease , Coronary Angiography
8.
Arq. bras. cardiol ; 64(5): 465-468, Mai. 1995.
Article in Portuguese | LILACS | ID: lil-319714

ABSTRACT

We describe a coronary angioplasty procedure performed by transradial approach, on a 53 year old male with a reestenotic lesion in his right coronary artery, done 19 months after the initial dilatation. This is a new technique and has not been applied in our country.


Subject(s)
Humans , Male , Middle Aged , Radial Artery , Coronary Disease , Angioplasty, Balloon, Coronary/methods , Stents , Angioplasty, Balloon, Coronary/economics , Length of Stay
SELECTION OF CITATIONS
SEARCH DETAIL